GridSense – Smart Grid Management & Live Fault Localization
Custom EasyEDA 2-Layer PCB, Master-Slave ESP32 Nodes, Graph-Based LCA Fault Localization, Interactive GIS SCADA, and Automated WhatsApp Alerting.
Custom 2-Layer PCB
Engineered from schematic to 3D CAD modeling in EasyEDA. Fabricated FR4 boards for both Master and Slave telemetry nodes.
LCA Fault Localization
Graph traversal algorithm (Lowest Common Ancestor) pinpoints the exact failure pole (e.g., gs_p9) when downstream customers trip.
WhatsApp Alerts
Dispatches automated incident reports via WhatsApp to linemen and affected consumers with exact GPS coordinates and repair scope.
Majestronics Expo
Demonstrated live at Majestronics Project Expo with a physical scale-model transmission grid, miniature utility poles, and real fault cuts.
// PROJECT MEDIA & HARDWARE GALLERY
13 High-Resolution Assets: SCADA, EasyEDA CAD, Custom PCBs, & Expo Showcase
Live Fault Analysis & LCA Node Localization
Root-cause identification pinpointing pole gs_p9 as the exact point of line failure across downstream consumers.
Designed on EasyEDA & Custom Manufactured
The GridSense hardware was architected from scratch using EasyEDA. To eliminate the wiring chaos, RF signal attenuation, and physical instability of breadboards, custom 2-layer PCBs were routed, modeled in 3D, and manufactured specifically for the Master Coordinator and Slave Pole Nodes.
Circuit & 3D CAD Modeling
Schematic titled grid_sense - transmeter and receiver (EasyEDA V1.0). Integrates ESP32-WROOM DevKit, NRF24L01 RF module header, AMS1117-3.3V LDO, I2C OLED display, and tactile reset/trigger buttons.
2-Layer FR4 Boards
Fabricated with green solder mask, silkscreen text "GRIDSENSE TRANSMITTER & RECEIVER", wide ground copper pours to isolate RF noise, and standard HASL pads for reliable hand soldering.
Master & Slave Nodes
Fully populated with socketed ESP32 modules, high-gain external SMA antennas for long-distance pole-to-pole RF transmission, 0.96" OLED diagnostic screen, and screw terminal blocks for sensor feeds.
Physical Scale Grid & Live Fault Demonstration
At the Majestronics Project Expo, GridSense was showcased using a fully operational miniature distribution grid. Sathasivam designed and erected scale-model 3D transmission poles with real electrical conductors running between transformers and load meters.
- Physical Fault Simulation: Evaluators simulated live line cuts and high-resistance faults directly on the scale conductors.
- Sub-Second Detection: The Slave node detected current disruption and transmitted an RF telemetry packet to the Master ESP32 coordinator.
- Instant SCADA & WhatsApp: The live web portal on the presenter laptop updated the Trichy Engineering College grid map in real-time while dispatching automated WhatsApp alert messages to judges!
// LCA FAULT LOCALIZATION ENGINE
Root Cause FinderIn conventional electrical distribution grids, identifying whether a blackout is caused by a tripped primary feeder, a collapsed transmission pole, or an individual customer branch requires hours of manual line patrol.
GridSense solves this through graph topology mapping and LCA (Lowest Common Ancestor) analysis:
Live Fault & WhatsApp Alert Simulator
Simulate a physical line fault at pole gs_p9 to trigger the LCA diagnostic engine and watch the automated WhatsApp notification dispatch:
Master-Slave RF Network Topology
The distributed physical tier consists of custom ESP32 monitoring hubs installed at step-down transformers and distribution poles.
- Master Node: ESP32 coordinator receiving packet streams from slave poles via NRF24L01 RF mesh and pushing telemetry via HTTPS to Cloudflare Pages edge workers.
- Slave Nodes: Low-power ESP32 edge units placed at distribution poles monitoring 3-phase current transformers (CTs) and voltage sensing dividers.
- Zero Blind Spots: Even during wide-area cellular or grid brownouts, the local NRF24L01 RF link maintains sub-second communications between nearby poles.
gridsense.pages.dev
Explore the live SCADA platform featuring the real Trichy Engineering College grid map, transformer registry, consumer billing, and fault telemetry.
System Specifications
WhatsApp Alert Subsystem
When the LCA algorithm flags a pole failure, a serverless webhook automatically formats the incident payload and triggers the WhatsApp Business API.
Sathasivam K