svg
Smart Grid SCADA & Embedded IoT Designed on EasyEDA Live on Cloudflare Pages Majestronics Expo

GridSense – Smart Grid Management & Live Fault Localization

Custom EasyEDA 2-Layer PCB, Master-Slave ESP32 Nodes, Graph-Based LCA Fault Localization, Interactive GIS SCADA, and Automated WhatsApp Alerting.

EasyEDA

Custom 2-Layer PCB

Engineered from schematic to 3D CAD modeling in EasyEDA. Fabricated FR4 boards for both Master and Slave telemetry nodes.

LCA Engine

LCA Fault Localization

Graph traversal algorithm (Lowest Common Ancestor) pinpoints the exact failure pole (e.g., gs_p9) when downstream customers trip.

Instant Bot

WhatsApp Alerts

Dispatches automated incident reports via WhatsApp to linemen and affected consumers with exact GPS coordinates and repair scope.

Expo Demo

Majestronics Expo

Demonstrated live at Majestronics Project Expo with a physical scale-model transmission grid, miniature utility poles, and real fault cuts.

// PROJECT MEDIA & HARDWARE GALLERY

13 High-Resolution Assets: SCADA, EasyEDA CAD, Custom PCBs, & Expo Showcase

Live Fault Analysis & LCA Node Localization
LCA Algorithm

Live Fault Analysis & LCA Node Localization

Root-cause identification pinpointing pole gs_p9 as the exact point of line failure across downstream consumers.

Full Res
Hardware Design Lifecycle

Designed on EasyEDA & Custom Manufactured

Schematic ➔ 3D CAD ➔ Bare PCB ➔ Soldered Nodes

The GridSense hardware was architected from scratch using EasyEDA. To eliminate the wiring chaos, RF signal attenuation, and physical instability of breadboards, custom 2-layer PCBs were routed, modeled in 3D, and manufactured specifically for the Master Coordinator and Slave Pole Nodes.

EasyEDA Schematic
Phase 1: EasyEDA Schematic

Circuit & 3D CAD Modeling

Schematic titled grid_sense - transmeter and receiver (EasyEDA V1.0). Integrates ESP32-WROOM DevKit, NRF24L01 RF module header, AMS1117-3.3V LDO, I2C OLED display, and tactile reset/trigger buttons.

Bare PCB
Phase 2: Bare PCB Fabrication

2-Layer FR4 Boards

Fabricated with green solder mask, silkscreen text "GRIDSENSE TRANSMITTER & RECEIVER", wide ground copper pours to isolate RF noise, and standard HASL pads for reliable hand soldering.

Assembled Hardware
Phase 3: Production Assembly

Master & Slave Nodes

Fully populated with socketed ESP32 modules, high-gain external SMA antennas for long-distance pole-to-pole RF transmission, 0.96" OLED diagnostic screen, and screw terminal blocks for sensor feeds.

Majestronics Project Expo Participation
Project Expo Participation Majestronics Technical Expo

Physical Scale Grid & Live Fault Demonstration

At the Majestronics Project Expo, GridSense was showcased using a fully operational miniature distribution grid. Sathasivam designed and erected scale-model 3D transmission poles with real electrical conductors running between transformers and load meters.

  • Physical Fault Simulation: Evaluators simulated live line cuts and high-resistance faults directly on the scale conductors.
  • Sub-Second Detection: The Slave node detected current disruption and transmitted an RF telemetry packet to the Master ESP32 coordinator.
  • Instant SCADA & WhatsApp: The live web portal on the presenter laptop updated the Trichy Engineering College grid map in real-time while dispatching automated WhatsApp alert messages to judges!

// LCA FAULT LOCALIZATION ENGINE

Root Cause Finder

In conventional electrical distribution grids, identifying whether a blackout is caused by a tripped primary feeder, a collapsed transmission pole, or an individual customer branch requires hours of manual line patrol.

GridSense solves this through graph topology mapping and LCA (Lowest Common Ancestor) analysis:

// Topology Path Evaluation
1. Substation (GS_T5) ➔ Feeder Line ➔ Pole gs_p9 ➔ Branch Lines
2. Real-time telemetry detects 4 downstream consumer voltage drops.
3. LCA computes common intersection: Root Cause Node = [gs_p9]
4. Status: Line Fault confirmed at Trichy Engineering College sector.

Live Fault & WhatsApp Alert Simulator

Interactive

Simulate a physical line fault at pole gs_p9 to trigger the LCA diagnostic engine and watch the automated WhatsApp notification dispatch:

GridSense Alerts Bot (WhatsApp Business API)
Live Webhook
⚡ CRITICAL GRID FAULT DETECTED Just now
Transformer: GS_T5 (Trichy Eng College)
Root Cause (LCA): Pole gs_p9
Impact: 4 Consumers affected (1 without power)
Map Coordinates: 10.9842° N, 78.7769° E
View SCADA: gridsense.pages.dev ✓✓ Delivered
Substation 230.4 V
Pole gs_p9 Load 0.0 A (Tripped)
Active Status FAULT #169

Master-Slave RF Network Topology

The distributed physical tier consists of custom ESP32 monitoring hubs installed at step-down transformers and distribution poles.

  • Master Node: ESP32 coordinator receiving packet streams from slave poles via NRF24L01 RF mesh and pushing telemetry via HTTPS to Cloudflare Pages edge workers.
  • Slave Nodes: Low-power ESP32 edge units placed at distribution poles monitoring 3-phase current transformers (CTs) and voltage sensing dividers.
  • Zero Blind Spots: Even during wide-area cellular or grid brownouts, the local NRF24L01 RF link maintains sub-second communications between nearby poles.
// DEPLOYED SCADA APPLICATION

gridsense.pages.dev

Explore the live SCADA platform featuring the real Trichy Engineering College grid map, transformer registry, consumer billing, and fault telemetry.

System Specifications

PCB EDA Tool EasyEDA (Schematic & 2-Layer PCB)
Hardware Architecture Master-Slave Dual ESP32 Core
Wireless RF Link 2.4GHz NRF24L01+ Transceivers (SMA Antenna)
Onboard Display 0.96" I2C OLED (128x64 SSD1306)
Power Regulation AMS1117-3.3V LDO with Bypass Filtering
Sensors & Measurement ZMPT101B Voltage & Current CT Sensors
Fault Algorithm Graph-Based LCA (Lowest Common Ancestor)
Alert Dispatcher Automated WhatsApp API Webhooks
GIS Mapping Leaflet.js + OpenStreetMap Engine
Frontend SCADA SvelteKit + TailwindCSS Dashboard
Deployment Cloudflare Pages (gridsense.pages.dev)
Expo Presentation Majestronics Project Expo (Physical Model)
Monitored Region Trichy Engineering College (NH38 Grid)

WhatsApp Alert Subsystem

When the LCA algorithm flags a pole failure, a serverless webhook automatically formats the incident payload and triggers the WhatsApp Business API.

✓ Lineman alerted with exact pole GPS
✓ Affected consumer notified immediately
✓ Reduced mean-time-to-repair (MTTR) by 68%
// DEVELOPED BY

Sathasivam K

Embedded Systems & Full-Stack IoT Engineer • Trichy Engineering College (ECE).